Resist the urge to adjust the cool settings lower than the recommended temperature in an effort to reduce the initial cooling period of 24 hours; Whirlpool notes that doing this will not cool your fridge any faster during the initial cooling period. Enter model number to search for the required part specific to your product, Browse our parts categories to select from a variety of parts for your product. We have compiled some of the most common reasons for the ineffectiveness of your machine. You may be pleasantly surprised to find that some solutions are easy to diagnose and resolve, even if you're typically not a fix-it guy or gal. (Seller assured us they all functioned great, they were just upgrading.) Whirlpool refrigerators have an electrically control damper that moves cold air from the freezer to the refrigerator section. Check the damper control to determine if it is broken or stuck closed. If the thermistor is defective, the compressor and evaporator fan may not run when necessary, or may run too frequently. Most likely the compressor is not starting as one of these components are bad.-RR. Start doing it yourself with the confidence that comes with 100+ years of experience. Shipping all 7 days! Without this fan refrigerant won’t cool enough to maintain the refrigerator’s temperature. The evaporator fan motor draws cold air over the evaporator coils and circulates it throughout the freezer. Before your food begins to spoil, follow a short troubleshooting list to see if you can take care of the problem first without having to call a refrigerator technician. Her writing 05/21/2019 by Shadiq. David. and DIY projects, banking, finance, law and tax. Why Is My Refrigerator Not Cooling? If the defrost thermostat and defrost heater are working properly, the defrost control board is likely defective and will need to be replace... Glass Tray, Coupler & Support Roller Parts. Join Repair Clinic's VIP email list for 10% off, plus other discounts and tips! individual clients. You may have even noticed your refrigerator is noisy, which can be due to your fridge working harder to maintain a proper temperature. We've got millions of parts, hundreds of brands, and thousands of step-by-step videos— everything you need to find it, fix it and finish the job right. A common solution for your fridge and freezer not cooling requires a little housekeeping. Victoria Lee Blackstone is a horticulturist and If it's got power but is not running, wack it. 1. Control boards are often misdiagnosed—before replacing the control board, first test all of the more commonly defective components. If the defrost control board fails, the refrigerator will not run the defrost cycle, and frost will continue to accumulate on the evaporator coils. If not, lower it by 1 more degree F and wait another 24 hours, repeating this procedure if necessary. Additionally, if the motor is unusually noisy, replace it. The compressor is the pump that circulates refrigerant through the condenser coil. If the evaporator coils are frosted over, the airflow through the coils will be restricted, causing the refrigerator not to cool. Faulty Door Gaskets. Clogged coils can cause poor cooling. To determine if the evaporator fan motor is defective, try turning the fan blade by hand. Clean the Condenser … A Whirlpool fridge not cooling means a shorter preservation life for all your refrigerated food than you're expecting. The door gaskets in a refrigerator ensure a sealed closure every time you shut the door. If your Whirlpool refrigerator is newly installed, cooling is not instantaneous; it takes a little while for it to cool completely. Already ordered? a professional writer who has authored research-based scientific/technical The evaporator fan motor draws cold air over the evaporator coils and circulates it throughout the freezer. If the damper does not open properly, it won’t let enough cold air into the refrigerator. A stuck or broken evaporator fan usually makes chirping or squealing sounds. To determine if the thermistor is defective, test it with a multimeter. Check to make sure nothing is stuck in the condenser fan and that it spins freely (models with coils on the back won’t have a fan). If the control board is faulty, it may stop sending voltage to the compressor or fan motors. If the evaporator fan is not working, the freezer or refrigerator will not cool adequately. The air damper control opens and closes to let the proper amount of cold air into the refrigerator compartment. To do this, unplug the fridge and pull it out. 01 - Condenser Coils are Dirty. The evaporator fan is located inside the freezer compartment, near the coils, and covered by a fan cover. 6,129. January 18, 2016 at 5:50 pm. The condenser coils are usually located under the refrigerator. Consult your user manual for the exact location of the condenser coil and the removal steps for the metal grille or kick plate that covers the coil. If your fridge is not cooling and this is accompanied by increased vibration and squealing noise whenever you open your fridge, then the likely cause of both problems is a faulty evaporator fan. expertise covers diverse industries, including horticulture, home maintenance Before you attempt to clean your refrigerator's condenser coil, unplug your fridge or turn off the circuit breaker that supplies power to it. If the defrost heater assembly is defective, frost will continue to accumulate on the evaporator coils, and the coils will become plugged with frost. papers, horticultural articles, and magazine and newspaper columns. Dirty condenser coils are the most common cause for a Whirlpool refrigerator not cooling. Whirlpool presets the refrigerator cooling control at the factory to 37 degrees F (0 degrees F for the freezer). The thermistor monitors the refrigerator temperature and sends the temperature reading to the control board. The temperature control board provides voltage to the compressor and fan motors. Whirlpool Condenser Coils are Dirty. Reply. And for the most part, these are also the temperatures at which you want to maintain your fridge's settings. The start relay is what signals the compressor to run, and the start capacitor boosts power to the compressor when it starts.